If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
high frequency products fbar filter D6HH1G960BH97 features item summary w-cdma / cdma, 1008 lifecycle stage mass production standard packaging quantity (minimum) taping embossed 3000 , 10000pcs products characteristics table temperature range -20 to +85 band(3gpp) b2 band(3gpp2) bc1 use wcdma / cdma transmitting / receiving duplexer insertion loss 2.6/2.5db attenuation 56/59db rohs compliance yes halogen free yes soldering method reflow external dimensions l 2.5mm +0.1:-0.1 w 2mm +0.1:-0.1 t 0.65mm max 2015.06.03 powered by tcpdf (www.tcpdf.org) 1 / 1 spec sheet http://www.ty-top.com t h e d a t a i s r e f e r e n c e o n l y . e l e c t r i c a l c h a r a c t e r i s t i c s v a r y d e p e n d i n g o n e n v i r o n m e n t o r m e a s u r e m e n t c o n d i t i o n . t a i y o y u d e n r e s e r v e s t h e r i g h t t o m a ke c h a n g e t o t h e d a t e a t a n y t i m e w i t h o u t n o t i c e . b e f o r e m a k i n g f i n a l s e l e c t i o n , p l e a s e c h e c k p r o d u c t s p e c i f i c a t i o n . msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part table 1 - 1 . electrical specification item condition (mhz) specification unit remarks min typ max tx to ant insertion loss 1850.48~1909.52 - 2.6 3.3 db (*1 ) - - 3.0 (*2) 1850.625 ~ 1909.375 - 2.6 3. 5 - 30 ~ +85 o c (*3) ripple (any 5mhz) 1 850.48~1909.52 - - 1.5 db vswr ant 1850.48~1909.52 - 1.7 2.2 - tx - 1.8 2.2 - input power 1850.48~1909.52 29dbm, ta=+50 o c, 50kh, cw dbm absolute attenuation 10 ~ 728 30 45 - db 728 ~ 764 40 46 - db 869 ~ 894 40 48 - db 1565.42 ~ 1 573.374 43 50 - db 1573.374~1577.466 43 50 - db 1577.466~1585.42 43 50 - db 1597.5515~1605.886 43 50 - db 1605.886 ~1680 30 41 - db 1930 .48 ~ 19 89.52 43 54 - db 2110 ~ 2155 33 44 - db 2400 ~ 2500 30 35 - db 3690 ~ 3830 20 2 7 - db 5150 ~ 5350 15 19 - db 5540 ~ 5860 13 16 - db 7390 ~ 7650 10 18 - db (*1 ) specification of insertion loss ex cludes loss that comes from the test board. ( approximately 0.15db) (*2) the integrated isolation over channel band width (+/ - 1. 92mhz) (*3 ) the integrated isolation over channel band width (+/ - 0.625mhz ) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part table 1 - 2. electrical specification item condition (mhz) specification unit remarks min typ max ant to rx insertion loss 1930.48~1989.52 - 2.5 3.5 db (*1 ) ripple (any 5mhz) 1930.48~1989.52 - - 1.5 db phase balance 1930.48~1989.52 - 13 - 5 +3 +13 deg amplitude balance 1930.48~1989.52 - 1.7 - 0.6 +0.6 +1.7 db vswr ant 1930.48~1989.52 - 1.8 2.1 - rx - 1.8 2.2 - absolute attenuation 1 ~ 1850 30 38 - db 1765 ~ 1835 30 46 - db 1850 .48 ~ 19 89.52 45 55 - db 2005 ~ 2050 2 1 0 - db 2050 ~ 2075 25 43 - db 2400 ~ 2484 40 51 - db 2810 ~ 2910 25 50 - db 3755 ~ 3905 30 47 - db 5625 ~ 5815 30 42 - db tx to rx isolation (differential) 1574 ~ 1577 40 63 - db 1850.48~1909.52 52 56 - db 1932.4 ~ 1987.6 50 59 - db (*2) 1931.25~1988.75 44 59 - db - 30 ~ - 20 o c (*3) 48 - db - 20 ~ - 10 o c (*3) 50 - - db - 10 ~ +85 o c (*3) 3700 ~ 3820 30 52 - db 5550 ~ 5850 30 44 - db c ommon mode isolation 1850.48~1909.52 46 50 - db terminating impedance tx port 50 single - ended rx port 100 // none differential ant port 50 single - ended operating temperature - 20 to +85 o c device size (l typ. x w typ. x h max. ) 2.5 x 2.0 x 0.65 mm (*1 ) specification of insertion loss ex cludes loss that comes from the test board. ( approximately 0.1 5 db) (*2) the integrated isolation over channel band width (+/ - 1.92mhz) (*3 ) the integrated isolation over channel band width (+/ - 0.625mhz) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part dimensio ns < top view > < side view > < bottom view > unit: mm pin configuration pin no. pin name description 1 rx receiver pin (balanced) 2 gnd ground pin 3 tx transmitter pin 4 gnd ground pin 5 gnd ground pin 6 ant antenna pin 7 gnd ground pin 8 rx receiver pin (balanced) 9 gnd ground pin figure 1. dimensions and pin assignment <6> <2> <5> <3> <1> <2> <7> <8> <6> <3> <4> <5> <4> <1> <7> <8> max index <9> msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part evaluation circuit recommended foot print pattern unit: mm figure 2. recommended foot print pattern external appearance in chip carrier common gnd 6 8 1 2,4 5,7,9 ant gnd 1~9 : pin no. 3 tx balanced rx (100ohm) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to ant ant to rx figure 3 - 1. electrical characteristics these data in clude loss that comes from the test board. ( approximately 0.15db) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to ant, ant to rx tx to rx isolation figure 3 - 2. electrical characteristics these data in clude loss that comes from the test board. ( approximately 0.15db) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx port figure 3 - 3. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part rx port figure 3 - 4. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part ant port figure 3 - 5. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part ant to rx (amplitude balance) ant to rx (phase balance) figure 3 - 6. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to ant (wide span) ant to rx (wide span) figure 3 - 7. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to rx (wide span) common mode isolation figure 3 - 8. electrical charact eristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part order i ng code ordering code packing reel size status d6 hh 1g960 bh9 7 - z tape & reel 3 ,000 pcs . mp d6hh1g960bh9 7 - z a tape & reel less than 3,000 pcs. mp d6hh1g960bh9 7 - u tape & reel 10 ,000 pcs . mp d6hh1g960bh9 7 - u a tape & reel less than 10 ,000 pc s . mp d6hh1g960bh9 7 - q bulk few pcs . mp * minimum order quantity ( moq ) is assigned for each inquiry , please contact to sales representatives. . *mp : mass production notice all of the contents specified herein are subject to change without notice due to technical improvements, etc. please contact t aiyo y uden co., ltd. for further details of product specifications. please conduct validation and verification of products in actual condition of mounting and operating environment before commercial s hipment of the equipment. this product is for general electronics equipment such as audio - visual equipment, household electronics, office supplies, information services and telecommunications; therefore, in case this product is used for any medical equipm ent, space equipment, nuclear equipment or disaster prevention equipment, please contact t aiyo y uden in advance. in case this product is used for general electronics equipment or circuits which require high safety and high reliability, thoroughly evaluate on safety and add a protection circuit if necessary.
high frequency products fbar filter D6HH1G960BH97 features item summary w-cdma / cdma, 1008 lifecycle stage mass production standard packaging quantity (minimum) taping embossed 3000 , 10000pcs products characteristics table temperature range -20 to +85 band(3gpp) b2 band(3gpp2) bc1 use wcdma / cdma transmitting / receiving duplexer insertion loss 2.6/2.5db attenuation 56/59db rohs compliance yes halogen free yes soldering method reflow external dimensions l 2.5mm +0.1:-0.1 w 2mm +0.1:-0.1 t 0.65mm max 2015.06.03 powered by tcpdf (www.tcpdf.org) 1 / 1 spec sheet http://www.ty-top.com t h e d a t a i s r e f e r e n c e o n l y . e l e c t r i c a l c h a r a c t e r i s t i c s v a r y d e p e n d i n g o n e n v i r o n m e n t o r m e a s u r e m e n t c o n d i t i o n . t a i y o y u d e n r e s e r v e s t h e r i g h t t o m a ke c h a n g e t o t h e d a t e a t a n y t i m e w i t h o u t n o t i c e . b e f o r e m a k i n g f i n a l s e l e c t i o n , p l e a s e c h e c k p r o d u c t s p e c i f i c a t i o n . msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part table 1 - 1 . electrical specification item condition (mhz) specification unit remarks min typ max tx to ant insertion loss 1850.48~1909.52 - 2.6 3.3 db (*1 ) - - 3.0 (*2) 1850.625 ~ 1909.375 - 2.6 3. 5 - 30 ~ +85 o c (*3) ripple (any 5mhz) 1 850.48~1909.52 - - 1.5 db vswr ant 1850.48~1909.52 - 1.7 2.2 - tx - 1.8 2.2 - input power 1850.48~1909.52 29dbm, ta=+50 o c, 50kh, cw dbm absolute attenuation 10 ~ 728 30 45 - db 728 ~ 764 40 46 - db 869 ~ 894 40 48 - db 1565.42 ~ 1 573.374 43 50 - db 1573.374~1577.466 43 50 - db 1577.466~1585.42 43 50 - db 1597.5515~1605.886 43 50 - db 1605.886 ~1680 30 41 - db 1930 .48 ~ 19 89.52 43 54 - db 2110 ~ 2155 33 44 - db 2400 ~ 2500 30 35 - db 3690 ~ 3830 20 2 7 - db 5150 ~ 5350 15 19 - db 5540 ~ 5860 13 16 - db 7390 ~ 7650 10 18 - db (*1 ) specification of insertion loss ex cludes loss that comes from the test board. ( approximately 0.15db) (*2) the integrated isolation over channel band width (+/ - 1. 92mhz) (*3 ) the integrated isolation over channel band width (+/ - 0.625mhz ) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part table 1 - 2. electrical specification item condition (mhz) specification unit remarks min typ max ant to rx insertion loss 1930.48~1989.52 - 2.5 3.5 db (*1 ) ripple (any 5mhz) 1930.48~1989.52 - - 1.5 db phase balance 1930.48~1989.52 - 13 - 5 +3 +13 deg amplitude balance 1930.48~1989.52 - 1.7 - 0.6 +0.6 +1.7 db vswr ant 1930.48~1989.52 - 1.8 2.1 - rx - 1.8 2.2 - absolute attenuation 1 ~ 1850 30 38 - db 1765 ~ 1835 30 46 - db 1850 .48 ~ 19 89.52 45 55 - db 2005 ~ 2050 2 1 0 - db 2050 ~ 2075 25 43 - db 2400 ~ 2484 40 51 - db 2810 ~ 2910 25 50 - db 3755 ~ 3905 30 47 - db 5625 ~ 5815 30 42 - db tx to rx isolation (differential) 1574 ~ 1577 40 63 - db 1850.48~1909.52 52 56 - db 1932.4 ~ 1987.6 50 59 - db (*2) 1931.25~1988.75 44 59 - db - 30 ~ - 20 o c (*3) 48 - db - 20 ~ - 10 o c (*3) 50 - - db - 10 ~ +85 o c (*3) 3700 ~ 3820 30 52 - db 5550 ~ 5850 30 44 - db c ommon mode isolation 1850.48~1909.52 46 50 - db terminating impedance tx port 50 single - ended rx port 100 // none differential ant port 50 single - ended operating temperature - 20 to +85 o c device size (l typ. x w typ. x h max. ) 2.5 x 2.0 x 0.65 mm (*1 ) specification of insertion loss ex cludes loss that comes from the test board. ( approximately 0.1 5 db) (*2) the integrated isolation over channel band width (+/ - 1.92mhz) (*3 ) the integrated isolation over channel band width (+/ - 0.625mhz) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part dimensio ns < top view > < side view > < bottom view > unit: mm pin configuration pin no. pin name description 1 rx receiver pin (balanced) 2 gnd ground pin 3 tx transmitter pin 4 gnd ground pin 5 gnd ground pin 6 ant antenna pin 7 gnd ground pin 8 rx receiver pin (balanced) 9 gnd ground pin figure 1. dimensions and pin assignment <6> <2> <5> <3> <1> <2> <7> <8> <6> <3> <4> <5> <4> <1> <7> <8> max index <9> msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part evaluation circuit recommended foot print pattern unit: mm figure 2. recommended foot print pattern external appearance in chip carrier common gnd 6 8 1 2,4 5,7,9 ant gnd 1~9 : pin no. 3 tx balanced rx (100ohm) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to ant ant to rx figure 3 - 1. electrical characteristics these data in clude loss that comes from the test board. ( approximately 0.15db) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to ant, ant to rx tx to rx isolation figure 3 - 2. electrical characteristics these data in clude loss that comes from the test board. ( approximately 0.15db) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx port figure 3 - 3. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part rx port figure 3 - 4. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part ant port figure 3 - 5. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part ant to rx (amplitude balance) ant to rx (phase balance) figure 3 - 6. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to ant (wide span) ant to rx (wide span) figure 3 - 7. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to rx (wide span) common mode isolation figure 3 - 8. electrical charact eristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part order i ng code ordering code packing reel size status d6 hh 1g960 bh9 7 - z tape & reel 3 ,000 pcs . mp d6hh1g960bh9 7 - z a tape & reel less than 3,000 pcs. mp d6hh1g960bh9 7 - u tape & reel 10 ,000 pcs . mp d6hh1g960bh9 7 - u a tape & reel less than 10 ,000 pc s . mp d6hh1g960bh9 7 - q bulk few pcs . mp * minimum order quantity ( moq ) is assigned for each inquiry , please contact to sales representatives. . *mp : mass production notice all of the contents specified herein are subject to change without notice due to technical improvements, etc. please contact t aiyo y uden co., ltd. for further details of product specifications. please conduct validation and verification of products in actual condition of mounting and operating environment before commercial s hipment of the equipment. this product is for general electronics equipment such as audio - visual equipment, household electronics, office supplies, information services and telecommunications; therefore, in case this product is used for any medical equipm ent, space equipment, nuclear equipment or disaster prevention equipment, please contact t aiyo y uden in advance. in case this product is used for general electronics equipment or circuits which require high safety and high reliability, thoroughly evaluate on safety and add a protection circuit if necessary. high frequency products fbar filter D6HH1G960BH97 features item summary w-cdma / cdma, 1008 lifecycle stage mass production standard packaging quantity (minimum) taping embossed 3000 , 10000pcs products characteristics table temperature range -20 to +85 band(3gpp) b2 band(3gpp2) bc1 use wcdma / cdma transmitting / receiving duplexer insertion loss 2.6/2.5db attenuation 56/59db rohs compliance yes halogen free yes soldering method reflow external dimensions l 2.5mm +0.1:-0.1 w 2mm +0.1:-0.1 t 0.65mm max 2015.06.03 powered by tcpdf (www.tcpdf.org) 1 / 1 spec sheet http://www.ty-top.com t h e d a t a i s r e f e r e n c e o n l y . e l e c t r i c a l c h a r a c t e r i s t i c s v a r y d e p e n d i n g o n e n v i r o n m e n t o r m e a s u r e m e n t c o n d i t i o n . t a i y o y u d e n r e s e r v e s t h e r i g h t t o m a ke c h a n g e t o t h e d a t e a t a n y t i m e w i t h o u t n o t i c e . b e f o r e m a k i n g f i n a l s e l e c t i o n , p l e a s e c h e c k p r o d u c t s p e c i f i c a t i o n . msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part table 1 - 1 . electrical specification item condition (mhz) specification unit remarks min typ max tx to ant insertion loss 1850.48~1909.52 - 2.6 3.3 db (*1 ) - - 3.0 (*2) 1850.625 ~ 1909.375 - 2.6 3. 5 - 30 ~ +85 o c (*3) ripple (any 5mhz) 1 850.48~1909.52 - - 1.5 db vswr ant 1850.48~1909.52 - 1.7 2.2 - tx - 1.8 2.2 - input power 1850.48~1909.52 29dbm, ta=+50 o c, 50kh, cw dbm absolute attenuation 10 ~ 728 30 45 - db 728 ~ 764 40 46 - db 869 ~ 894 40 48 - db 1565.42 ~ 1 573.374 43 50 - db 1573.374~1577.466 43 50 - db 1577.466~1585.42 43 50 - db 1597.5515~1605.886 43 50 - db 1605.886 ~1680 30 41 - db 1930 .48 ~ 19 89.52 43 54 - db 2110 ~ 2155 33 44 - db 2400 ~ 2500 30 35 - db 3690 ~ 3830 20 2 7 - db 5150 ~ 5350 15 19 - db 5540 ~ 5860 13 16 - db 7390 ~ 7650 10 18 - db (*1 ) specification of insertion loss ex cludes loss that comes from the test board. ( approximately 0.15db) (*2) the integrated isolation over channel band width (+/ - 1. 92mhz) (*3 ) the integrated isolation over channel band width (+/ - 0.625mhz ) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part table 1 - 2. electrical specification item condition (mhz) specification unit remarks min typ max ant to rx insertion loss 1930.48~1989.52 - 2.5 3.5 db (*1 ) ripple (any 5mhz) 1930.48~1989.52 - - 1.5 db phase balance 1930.48~1989.52 - 13 - 5 +3 +13 deg amplitude balance 1930.48~1989.52 - 1.7 - 0.6 +0.6 +1.7 db vswr ant 1930.48~1989.52 - 1.8 2.1 - rx - 1.8 2.2 - absolute attenuation 1 ~ 1850 30 38 - db 1765 ~ 1835 30 46 - db 1850 .48 ~ 19 89.52 45 55 - db 2005 ~ 2050 2 1 0 - db 2050 ~ 2075 25 43 - db 2400 ~ 2484 40 51 - db 2810 ~ 2910 25 50 - db 3755 ~ 3905 30 47 - db 5625 ~ 5815 30 42 - db tx to rx isolation (differential) 1574 ~ 1577 40 63 - db 1850.48~1909.52 52 56 - db 1932.4 ~ 1987.6 50 59 - db (*2) 1931.25~1988.75 44 59 - db - 30 ~ - 20 o c (*3) 48 - db - 20 ~ - 10 o c (*3) 50 - - db - 10 ~ +85 o c (*3) 3700 ~ 3820 30 52 - db 5550 ~ 5850 30 44 - db c ommon mode isolation 1850.48~1909.52 46 50 - db terminating impedance tx port 50 single - ended rx port 100 // none differential ant port 50 single - ended operating temperature - 20 to +85 o c device size (l typ. x w typ. x h max. ) 2.5 x 2.0 x 0.65 mm (*1 ) specification of insertion loss ex cludes loss that comes from the test board. ( approximately 0.1 5 db) (*2) the integrated isolation over channel band width (+/ - 1.92mhz) (*3 ) the integrated isolation over channel band width (+/ - 0.625mhz) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part dimensio ns < top view > < side view > < bottom view > unit: mm pin configuration pin no. pin name description 1 rx receiver pin (balanced) 2 gnd ground pin 3 tx transmitter pin 4 gnd ground pin 5 gnd ground pin 6 ant antenna pin 7 gnd ground pin 8 rx receiver pin (balanced) 9 gnd ground pin figure 1. dimensions and pin assignment <6> <2> <5> <3> <1> <2> <7> <8> <6> <3> <4> <5> <4> <1> <7> <8> max index <9> msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part evaluation circuit recommended foot print pattern unit: mm figure 2. recommended foot print pattern external appearance in chip carrier common gnd 6 8 1 2,4 5,7,9 ant gnd 1~9 : pin no. 3 tx balanced rx (100ohm) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to ant ant to rx figure 3 - 1. electrical characteristics these data in clude loss that comes from the test board. ( approximately 0.15db) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to ant, ant to rx tx to rx isolation figure 3 - 2. electrical characteristics these data in clude loss that comes from the test board. ( approximately 0.15db) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx port figure 3 - 3. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part rx port figure 3 - 4. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part ant port figure 3 - 5. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part ant to rx (amplitude balance) ant to rx (phase balance) figure 3 - 6. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to ant (wide span) ant to rx (wide span) figure 3 - 7. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to rx (wide span) common mode isolation figure 3 - 8. electrical charact eristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part order i ng code ordering code packing reel size status d6 hh 1g960 bh9 7 - z tape & reel 3 ,000 pcs . mp d6hh1g960bh9 7 - z a tape & reel less than 3,000 pcs. mp d6hh1g960bh9 7 - u tape & reel 10 ,000 pcs . mp d6hh1g960bh9 7 - u a tape & reel less than 10 ,000 pc s . mp d6hh1g960bh9 7 - q bulk few pcs . mp * minimum order quantity ( moq ) is assigned for each inquiry , please contact to sales representatives. . *mp : mass production notice all of the contents specified herein are subject to change without notice due to technical improvements, etc. please contact t aiyo y uden co., ltd. for further details of product specifications. please conduct validation and verification of products in actual condition of mounting and operating environment before commercial s hipment of the equipment. this product is for general electronics equipment such as audio - visual equipment, household electronics, office supplies, information services and telecommunications; therefore, in case this product is used for any medical equipm ent, space equipment, nuclear equipment or disaster prevention equipment, please contact t aiyo y uden in advance. in case this product is used for general electronics equipment or circuits which require high safety and high reliability, thoroughly evaluate on safety and add a protection circuit if necessary. high frequency products fbar filter D6HH1G960BH97 features item summary w-cdma / cdma, 1008 lifecycle stage mass production standard packaging quantity (minimum) taping embossed 3000 , 10000pcs products characteristics table temperature range -20 to +85 band(3gpp) b2 band(3gpp2) bc1 use wcdma / cdma transmitting / receiving duplexer insertion loss 2.6/2.5db attenuation 56/59db rohs compliance yes halogen free yes soldering method reflow external dimensions l 2.5mm +0.1:-0.1 w 2mm +0.1:-0.1 t 0.65mm max 2015.06.03 powered by tcpdf (www.tcpdf.org) 1 / 1 spec sheet http://www.ty-top.com t h e d a t a i s r e f e r e n c e o n l y . e l e c t r i c a l c h a r a c t e r i s t i c s v a r y d e p e n d i n g o n e n v i r o n m e n t o r m e a s u r e m e n t c o n d i t i o n . t a i y o y u d e n r e s e r v e s t h e r i g h t t o m a ke c h a n g e t o t h e d a t e a t a n y t i m e w i t h o u t n o t i c e . b e f o r e m a k i n g f i n a l s e l e c t i o n , p l e a s e c h e c k p r o d u c t s p e c i f i c a t i o n . msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part table 1 - 1 . electrical specification item condition (mhz) specification unit remarks min typ max tx to ant insertion loss 1850.48~1909.52 - 2.6 3.3 db (*1 ) - - 3.0 (*2) 1850.625 ~ 1909.375 - 2.6 3. 5 - 30 ~ +85 o c (*3) ripple (any 5mhz) 1 850.48~1909.52 - - 1.5 db vswr ant 1850.48~1909.52 - 1.7 2.2 - tx - 1.8 2.2 - input power 1850.48~1909.52 29dbm, ta=+50 o c, 50kh, cw dbm absolute attenuation 10 ~ 728 30 45 - db 728 ~ 764 40 46 - db 869 ~ 894 40 48 - db 1565.42 ~ 1 573.374 43 50 - db 1573.374~1577.466 43 50 - db 1577.466~1585.42 43 50 - db 1597.5515~1605.886 43 50 - db 1605.886 ~1680 30 41 - db 1930 .48 ~ 19 89.52 43 54 - db 2110 ~ 2155 33 44 - db 2400 ~ 2500 30 35 - db 3690 ~ 3830 20 2 7 - db 5150 ~ 5350 15 19 - db 5540 ~ 5860 13 16 - db 7390 ~ 7650 10 18 - db (*1 ) specification of insertion loss ex cludes loss that comes from the test board. ( approximately 0.15db) (*2) the integrated isolation over channel band width (+/ - 1. 92mhz) (*3 ) the integrated isolation over channel band width (+/ - 0.625mhz ) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part table 1 - 2. electrical specification item condition (mhz) specification unit remarks min typ max ant to rx insertion loss 1930.48~1989.52 - 2.5 3.5 db (*1 ) ripple (any 5mhz) 1930.48~1989.52 - - 1.5 db phase balance 1930.48~1989.52 - 13 - 5 +3 +13 deg amplitude balance 1930.48~1989.52 - 1.7 - 0.6 +0.6 +1.7 db vswr ant 1930.48~1989.52 - 1.8 2.1 - rx - 1.8 2.2 - absolute attenuation 1 ~ 1850 30 38 - db 1765 ~ 1835 30 46 - db 1850 .48 ~ 19 89.52 45 55 - db 2005 ~ 2050 2 1 0 - db 2050 ~ 2075 25 43 - db 2400 ~ 2484 40 51 - db 2810 ~ 2910 25 50 - db 3755 ~ 3905 30 47 - db 5625 ~ 5815 30 42 - db tx to rx isolation (differential) 1574 ~ 1577 40 63 - db 1850.48~1909.52 52 56 - db 1932.4 ~ 1987.6 50 59 - db (*2) 1931.25~1988.75 44 59 - db - 30 ~ - 20 o c (*3) 48 - db - 20 ~ - 10 o c (*3) 50 - - db - 10 ~ +85 o c (*3) 3700 ~ 3820 30 52 - db 5550 ~ 5850 30 44 - db c ommon mode isolation 1850.48~1909.52 46 50 - db terminating impedance tx port 50 single - ended rx port 100 // none differential ant port 50 single - ended operating temperature - 20 to +85 o c device size (l typ. x w typ. x h max. ) 2.5 x 2.0 x 0.65 mm (*1 ) specification of insertion loss ex cludes loss that comes from the test board. ( approximately 0.1 5 db) (*2) the integrated isolation over channel band width (+/ - 1.92mhz) (*3 ) the integrated isolation over channel band width (+/ - 0.625mhz) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part dimensio ns < top view > < side view > < bottom view > unit: mm pin configuration pin no. pin name description 1 rx receiver pin (balanced) 2 gnd ground pin 3 tx transmitter pin 4 gnd ground pin 5 gnd ground pin 6 ant antenna pin 7 gnd ground pin 8 rx receiver pin (balanced) 9 gnd ground pin figure 1. dimensions and pin assignment <6> <2> <5> <3> <1> <2> <7> <8> <6> <3> <4> <5> <4> <1> <7> <8> max index <9> msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part evaluation circuit recommended foot print pattern unit: mm figure 2. recommended foot print pattern external appearance in chip carrier common gnd 6 8 1 2,4 5,7,9 ant gnd 1~9 : pin no. 3 tx balanced rx (100ohm) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to ant ant to rx figure 3 - 1. electrical characteristics these data in clude loss that comes from the test board. ( approximately 0.15db) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to ant, ant to rx tx to rx isolation figure 3 - 2. electrical characteristics these data in clude loss that comes from the test board. ( approximately 0.15db) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx port figure 3 - 3. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part rx port figure 3 - 4. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part ant port figure 3 - 5. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part ant to rx (amplitude balance) ant to rx (phase balance) figure 3 - 6. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to ant (wide span) ant to rx (wide span) figure 3 - 7. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to rx (wide span) common mode isolation figure 3 - 8. electrical charact eristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part order i ng code ordering code packing reel size status d6 hh 1g960 bh9 7 - z tape & reel 3 ,000 pcs . mp d6hh1g960bh9 7 - z a tape & reel less than 3,000 pcs. mp d6hh1g960bh9 7 - u tape & reel 10 ,000 pcs . mp d6hh1g960bh9 7 - u a tape & reel less than 10 ,000 pc s . mp d6hh1g960bh9 7 - q bulk few pcs . mp * minimum order quantity ( moq ) is assigned for each inquiry , please contact to sales representatives. . *mp : mass production notice all of the contents specified herein are subject to change without notice due to technical improvements, etc. please contact t aiyo y uden co., ltd. for further details of product specifications. please conduct validation and verification of products in actual condition of mounting and operating environment before commercial s hipment of the equipment. this product is for general electronics equipment such as audio - visual equipment, household electronics, office supplies, information services and telecommunications; therefore, in case this product is used for any medical equipm ent, space equipment, nuclear equipment or disaster prevention equipment, please contact t aiyo y uden in advance. in case this product is used for general electronics equipment or circuits which require high safety and high reliability, thoroughly evaluate on safety and add a protection circuit if necessary. high frequency products fbar filter D6HH1G960BH97 features item summary w-cdma / cdma, 1008 lifecycle stage mass production standard packaging quantity (minimum) taping embossed 3000 , 10000pcs products characteristics table temperature range -20 to +85 band(3gpp) b2 band(3gpp2) bc1 use wcdma / cdma transmitting / receiving duplexer insertion loss 2.6/2.5db attenuation 56/59db rohs compliance yes halogen free yes soldering method reflow external dimensions l 2.5mm +0.1:-0.1 w 2mm +0.1:-0.1 t 0.65mm max 2015.06.03 powered by tcpdf (www.tcpdf.org) 1 / 1 spec sheet http://www.ty-top.com t h e d a t a i s r e f e r e n c e o n l y . e l e c t r i c a l c h a r a c t e r i s t i c s v a r y d e p e n d i n g o n e n v i r o n m e n t o r m e a s u r e m e n t c o n d i t i o n . t a i y o y u d e n r e s e r v e s t h e r i g h t t o m a ke c h a n g e t o t h e d a t e a t a n y t i m e w i t h o u t n o t i c e . b e f o r e m a k i n g f i n a l s e l e c t i o n , p l e a s e c h e c k p r o d u c t s p e c i f i c a t i o n . msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part table 1 - 1 . electrical specification item condition (mhz) specification unit remarks min typ max tx to ant insertion loss 1850.48~1909.52 - 2.6 3.3 db (*1 ) - - 3.0 (*2) 1850.625 ~ 1909.375 - 2.6 3. 5 - 30 ~ +85 o c (*3) ripple (any 5mhz) 1 850.48~1909.52 - - 1.5 db vswr ant 1850.48~1909.52 - 1.7 2.2 - tx - 1.8 2.2 - input power 1850.48~1909.52 29dbm, ta=+50 o c, 50kh, cw dbm absolute attenuation 10 ~ 728 30 45 - db 728 ~ 764 40 46 - db 869 ~ 894 40 48 - db 1565.42 ~ 1 573.374 43 50 - db 1573.374~1577.466 43 50 - db 1577.466~1585.42 43 50 - db 1597.5515~1605.886 43 50 - db 1605.886 ~1680 30 41 - db 1930 .48 ~ 19 89.52 43 54 - db 2110 ~ 2155 33 44 - db 2400 ~ 2500 30 35 - db 3690 ~ 3830 20 2 7 - db 5150 ~ 5350 15 19 - db 5540 ~ 5860 13 16 - db 7390 ~ 7650 10 18 - db (*1 ) specification of insertion loss ex cludes loss that comes from the test board. ( approximately 0.15db) (*2) the integrated isolation over channel band width (+/ - 1. 92mhz) (*3 ) the integrated isolation over channel band width (+/ - 0.625mhz ) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part table 1 - 2. electrical specification item condition (mhz) specification unit remarks min typ max ant to rx insertion loss 1930.48~1989.52 - 2.5 3.5 db (*1 ) ripple (any 5mhz) 1930.48~1989.52 - - 1.5 db phase balance 1930.48~1989.52 - 13 - 5 +3 +13 deg amplitude balance 1930.48~1989.52 - 1.7 - 0.6 +0.6 +1.7 db vswr ant 1930.48~1989.52 - 1.8 2.1 - rx - 1.8 2.2 - absolute attenuation 1 ~ 1850 30 38 - db 1765 ~ 1835 30 46 - db 1850 .48 ~ 19 89.52 45 55 - db 2005 ~ 2050 2 1 0 - db 2050 ~ 2075 25 43 - db 2400 ~ 2484 40 51 - db 2810 ~ 2910 25 50 - db 3755 ~ 3905 30 47 - db 5625 ~ 5815 30 42 - db tx to rx isolation (differential) 1574 ~ 1577 40 63 - db 1850.48~1909.52 52 56 - db 1932.4 ~ 1987.6 50 59 - db (*2) 1931.25~1988.75 44 59 - db - 30 ~ - 20 o c (*3) 48 - db - 20 ~ - 10 o c (*3) 50 - - db - 10 ~ +85 o c (*3) 3700 ~ 3820 30 52 - db 5550 ~ 5850 30 44 - db c ommon mode isolation 1850.48~1909.52 46 50 - db terminating impedance tx port 50 single - ended rx port 100 // none differential ant port 50 single - ended operating temperature - 20 to +85 o c device size (l typ. x w typ. x h max. ) 2.5 x 2.0 x 0.65 mm (*1 ) specification of insertion loss ex cludes loss that comes from the test board. ( approximately 0.1 5 db) (*2) the integrated isolation over channel band width (+/ - 1.92mhz) (*3 ) the integrated isolation over channel band width (+/ - 0.625mhz) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part dimensio ns < top view > < side view > < bottom view > unit: mm pin configuration pin no. pin name description 1 rx receiver pin (balanced) 2 gnd ground pin 3 tx transmitter pin 4 gnd ground pin 5 gnd ground pin 6 ant antenna pin 7 gnd ground pin 8 rx receiver pin (balanced) 9 gnd ground pin figure 1. dimensions and pin assignment <6> <2> <5> <3> <1> <2> <7> <8> <6> <3> <4> <5> <4> <1> <7> <8> max index <9> msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part evaluation circuit recommended foot print pattern unit: mm figure 2. recommended foot print pattern external appearance in chip carrier common gnd 6 8 1 2,4 5,7,9 ant gnd 1~9 : pin no. 3 tx balanced rx (100ohm) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to ant ant to rx figure 3 - 1. electrical characteristics these data in clude loss that comes from the test board. ( approximately 0.15db) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to ant, ant to rx tx to rx isolation figure 3 - 2. electrical characteristics these data in clude loss that comes from the test board. ( approximately 0.15db) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx port figure 3 - 3. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part rx port figure 3 - 4. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part ant port figure 3 - 5. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part ant to rx (amplitude balance) ant to rx (phase balance) figure 3 - 6. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to ant (wide span) ant to rx (wide span) figure 3 - 7. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to rx (wide span) common mode isolation figure 3 - 8. electrical charact eristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part order i ng code ordering code packing reel size status d6 hh 1g960 bh9 7 - z tape & reel 3 ,000 pcs . mp d6hh1g960bh9 7 - z a tape & reel less than 3,000 pcs. mp d6hh1g960bh9 7 - u tape & reel 10 ,000 pcs . mp d6hh1g960bh9 7 - u a tape & reel less than 10 ,000 pc s . mp d6hh1g960bh9 7 - q bulk few pcs . mp * minimum order quantity ( moq ) is assigned for each inquiry , please contact to sales representatives. . *mp : mass production notice all of the contents specified herein are subject to change without notice due to technical improvements, etc. please contact t aiyo y uden co., ltd. for further details of product specifications. please conduct validation and verification of products in actual condition of mounting and operating environment before commercial s hipment of the equipment. this product is for general electronics equipment such as audio - visual equipment, household electronics, office supplies, information services and telecommunications; therefore, in case this product is used for any medical equipm ent, space equipment, nuclear equipment or disaster prevention equipment, please contact t aiyo y uden in advance. in case this product is used for general electronics equipment or circuits which require high safety and high reliability, thoroughly evaluate on safety and add a protection circuit if necessary. high frequency products fbar filter D6HH1G960BH97 features item summary w-cdma / cdma, 1008 lifecycle stage mass production standard packaging quantity (minimum) taping embossed 3000 , 10000pcs products characteristics table temperature range -20 to +85 band(3gpp) b2 band(3gpp2) bc1 use wcdma / cdma transmitting / receiving duplexer insertion loss 2.6/2.5db attenuation 56/59db rohs compliance yes halogen free yes soldering method reflow external dimensions l 2.5mm +0.1:-0.1 w 2mm +0.1:-0.1 t 0.65mm max 2015.06.03 powered by tcpdf (www.tcpdf.org) 1 / 1 spec sheet http://www.ty-top.com t h e d a t a i s r e f e r e n c e o n l y . e l e c t r i c a l c h a r a c t e r i s t i c s v a r y d e p e n d i n g o n e n v i r o n m e n t o r m e a s u r e m e n t c o n d i t i o n . t a i y o y u d e n r e s e r v e s t h e r i g h t t o m a ke c h a n g e t o t h e d a t e a t a n y t i m e w i t h o u t n o t i c e . b e f o r e m a k i n g f i n a l s e l e c t i o n , p l e a s e c h e c k p r o d u c t s p e c i f i c a t i o n . msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part table 1 - 1 . electrical specification item condition (mhz) specification unit remarks min typ max tx to ant insertion loss 1850.48~1909.52 - 2.6 3.3 db (*1 ) - - 3.0 (*2) 1850.625 ~ 1909.375 - 2.6 3. 5 - 30 ~ +85 o c (*3) ripple (any 5mhz) 1 850.48~1909.52 - - 1.5 db vswr ant 1850.48~1909.52 - 1.7 2.2 - tx - 1.8 2.2 - input power 1850.48~1909.52 29dbm, ta=+50 o c, 50kh, cw dbm absolute attenuation 10 ~ 728 30 45 - db 728 ~ 764 40 46 - db 869 ~ 894 40 48 - db 1565.42 ~ 1 573.374 43 50 - db 1573.374~1577.466 43 50 - db 1577.466~1585.42 43 50 - db 1597.5515~1605.886 43 50 - db 1605.886 ~1680 30 41 - db 1930 .48 ~ 19 89.52 43 54 - db 2110 ~ 2155 33 44 - db 2400 ~ 2500 30 35 - db 3690 ~ 3830 20 2 7 - db 5150 ~ 5350 15 19 - db 5540 ~ 5860 13 16 - db 7390 ~ 7650 10 18 - db (*1 ) specification of insertion loss ex cludes loss that comes from the test board. ( approximately 0.15db) (*2) the integrated isolation over channel band width (+/ - 1. 92mhz) (*3 ) the integrated isolation over channel band width (+/ - 0.625mhz ) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part table 1 - 2. electrical specification item condition (mhz) specification unit remarks min typ max ant to rx insertion loss 1930.48~1989.52 - 2.5 3.5 db (*1 ) ripple (any 5mhz) 1930.48~1989.52 - - 1.5 db phase balance 1930.48~1989.52 - 13 - 5 +3 +13 deg amplitude balance 1930.48~1989.52 - 1.7 - 0.6 +0.6 +1.7 db vswr ant 1930.48~1989.52 - 1.8 2.1 - rx - 1.8 2.2 - absolute attenuation 1 ~ 1850 30 38 - db 1765 ~ 1835 30 46 - db 1850 .48 ~ 19 89.52 45 55 - db 2005 ~ 2050 2 1 0 - db 2050 ~ 2075 25 43 - db 2400 ~ 2484 40 51 - db 2810 ~ 2910 25 50 - db 3755 ~ 3905 30 47 - db 5625 ~ 5815 30 42 - db tx to rx isolation (differential) 1574 ~ 1577 40 63 - db 1850.48~1909.52 52 56 - db 1932.4 ~ 1987.6 50 59 - db (*2) 1931.25~1988.75 44 59 - db - 30 ~ - 20 o c (*3) 48 - db - 20 ~ - 10 o c (*3) 50 - - db - 10 ~ +85 o c (*3) 3700 ~ 3820 30 52 - db 5550 ~ 5850 30 44 - db c ommon mode isolation 1850.48~1909.52 46 50 - db terminating impedance tx port 50 single - ended rx port 100 // none differential ant port 50 single - ended operating temperature - 20 to +85 o c device size (l typ. x w typ. x h max. ) 2.5 x 2.0 x 0.65 mm (*1 ) specification of insertion loss ex cludes loss that comes from the test board. ( approximately 0.1 5 db) (*2) the integrated isolation over channel band width (+/ - 1.92mhz) (*3 ) the integrated isolation over channel band width (+/ - 0.625mhz) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part dimensio ns < top view > < side view > < bottom view > unit: mm pin configuration pin no. pin name description 1 rx receiver pin (balanced) 2 gnd ground pin 3 tx transmitter pin 4 gnd ground pin 5 gnd ground pin 6 ant antenna pin 7 gnd ground pin 8 rx receiver pin (balanced) 9 gnd ground pin figure 1. dimensions and pin assignment <6> <2> <5> <3> <1> <2> <7> <8> <6> <3> <4> <5> <4> <1> <7> <8> max index <9> msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part evaluation circuit recommended foot print pattern unit: mm figure 2. recommended foot print pattern external appearance in chip carrier common gnd 6 8 1 2,4 5,7,9 ant gnd 1~9 : pin no. 3 tx balanced rx (100ohm) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to ant ant to rx figure 3 - 1. electrical characteristics these data in clude loss that comes from the test board. ( approximately 0.15db) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to ant, ant to rx tx to rx isolation figure 3 - 2. electrical characteristics these data in clude loss that comes from the test board. ( approximately 0.15db) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx port figure 3 - 3. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part rx port figure 3 - 4. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part ant port figure 3 - 5. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part ant to rx (amplitude balance) ant to rx (phase balance) figure 3 - 6. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to ant (wide span) ant to rx (wide span) figure 3 - 7. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to rx (wide span) common mode isolation figure 3 - 8. electrical charact eristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part order i ng code ordering code packing reel size status d6 hh 1g960 bh9 7 - z tape & reel 3 ,000 pcs . mp d6hh1g960bh9 7 - z a tape & reel less than 3,000 pcs. mp d6hh1g960bh9 7 - u tape & reel 10 ,000 pcs . mp d6hh1g960bh9 7 - u a tape & reel less than 10 ,000 pc s . mp d6hh1g960bh9 7 - q bulk few pcs . mp * minimum order quantity ( moq ) is assigned for each inquiry , please contact to sales representatives. . *mp : mass production notice all of the contents specified herein are subject to change without notice due to technical improvements, etc. please contact t aiyo y uden co., ltd. for further details of product specifications. please conduct validation and verification of products in actual condition of mounting and operating environment before commercial s hipment of the equipment. this product is for general electronics equipment such as audio - visual equipment, household electronics, office supplies, information services and telecommunications; therefore, in case this product is used for any medical equipm ent, space equipment, nuclear equipment or disaster prevention equipment, please contact t aiyo y uden in advance. in case this product is used for general electronics equipment or circuits which require high safety and high reliability, thoroughly evaluate on safety and add a protection circuit if necessary. high frequency products fbar filter D6HH1G960BH97 features item summary w-cdma / cdma, 1008 lifecycle stage mass production standard packaging quantity (minimum) taping embossed 3000 , 10000pcs products characteristics table temperature range -20 to +85 band(3gpp) b2 band(3gpp2) bc1 use wcdma / cdma transmitting / receiving duplexer insertion loss 2.6/2.5db attenuation 56/59db rohs compliance yes halogen free yes soldering method reflow external dimensions l 2.5mm +0.1:-0.1 w 2mm +0.1:-0.1 t 0.65mm max 2015.06.03 powered by tcpdf (www.tcpdf.org) 1 / 1 spec sheet http://www.ty-top.com t h e d a t a i s r e f e r e n c e o n l y . e l e c t r i c a l c h a r a c t e r i s t i c s v a r y d e p e n d i n g o n e n v i r o n m e n t o r m e a s u r e m e n t c o n d i t i o n . t a i y o y u d e n r e s e r v e s t h e r i g h t t o m a ke c h a n g e t o t h e d a t e a t a n y t i m e w i t h o u t n o t i c e . b e f o r e m a k i n g f i n a l s e l e c t i o n , p l e a s e c h e c k p r o d u c t s p e c i f i c a t i o n . msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part table 1 - 1 . electrical specification item condition (mhz) specification unit remarks min typ max tx to ant insertion loss 1850.48~1909.52 - 2.6 3.3 db (*1 ) - - 3.0 (*2) 1850.625 ~ 1909.375 - 2.6 3. 5 - 30 ~ +85 o c (*3) ripple (any 5mhz) 1 850.48~1909.52 - - 1.5 db vswr ant 1850.48~1909.52 - 1.7 2.2 - tx - 1.8 2.2 - input power 1850.48~1909.52 29dbm, ta=+50 o c, 50kh, cw dbm absolute attenuation 10 ~ 728 30 45 - db 728 ~ 764 40 46 - db 869 ~ 894 40 48 - db 1565.42 ~ 1 573.374 43 50 - db 1573.374~1577.466 43 50 - db 1577.466~1585.42 43 50 - db 1597.5515~1605.886 43 50 - db 1605.886 ~1680 30 41 - db 1930 .48 ~ 19 89.52 43 54 - db 2110 ~ 2155 33 44 - db 2400 ~ 2500 30 35 - db 3690 ~ 3830 20 2 7 - db 5150 ~ 5350 15 19 - db 5540 ~ 5860 13 16 - db 7390 ~ 7650 10 18 - db (*1 ) specification of insertion loss ex cludes loss that comes from the test board. ( approximately 0.15db) (*2) the integrated isolation over channel band width (+/ - 1. 92mhz) (*3 ) the integrated isolation over channel band width (+/ - 0.625mhz ) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part table 1 - 2. electrical specification item condition (mhz) specification unit remarks min typ max ant to rx insertion loss 1930.48~1989.52 - 2.5 3.5 db (*1 ) ripple (any 5mhz) 1930.48~1989.52 - - 1.5 db phase balance 1930.48~1989.52 - 13 - 5 +3 +13 deg amplitude balance 1930.48~1989.52 - 1.7 - 0.6 +0.6 +1.7 db vswr ant 1930.48~1989.52 - 1.8 2.1 - rx - 1.8 2.2 - absolute attenuation 1 ~ 1850 30 38 - db 1765 ~ 1835 30 46 - db 1850 .48 ~ 19 89.52 45 55 - db 2005 ~ 2050 2 1 0 - db 2050 ~ 2075 25 43 - db 2400 ~ 2484 40 51 - db 2810 ~ 2910 25 50 - db 3755 ~ 3905 30 47 - db 5625 ~ 5815 30 42 - db tx to rx isolation (differential) 1574 ~ 1577 40 63 - db 1850.48~1909.52 52 56 - db 1932.4 ~ 1987.6 50 59 - db (*2) 1931.25~1988.75 44 59 - db - 30 ~ - 20 o c (*3) 48 - db - 20 ~ - 10 o c (*3) 50 - - db - 10 ~ +85 o c (*3) 3700 ~ 3820 30 52 - db 5550 ~ 5850 30 44 - db c ommon mode isolation 1850.48~1909.52 46 50 - db terminating impedance tx port 50 single - ended rx port 100 // none differential ant port 50 single - ended operating temperature - 20 to +85 o c device size (l typ. x w typ. x h max. ) 2.5 x 2.0 x 0.65 mm (*1 ) specification of insertion loss ex cludes loss that comes from the test board. ( approximately 0.1 5 db) (*2) the integrated isolation over channel band width (+/ - 1.92mhz) (*3 ) the integrated isolation over channel band width (+/ - 0.625mhz) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part dimensio ns < top view > < side view > < bottom view > unit: mm pin configuration pin no. pin name description 1 rx receiver pin (balanced) 2 gnd ground pin 3 tx transmitter pin 4 gnd ground pin 5 gnd ground pin 6 ant antenna pin 7 gnd ground pin 8 rx receiver pin (balanced) 9 gnd ground pin figure 1. dimensions and pin assignment <6> <2> <5> <3> <1> <2> <7> <8> <6> <3> <4> <5> <4> <1> <7> <8> max index <9> msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part evaluation circuit recommended foot print pattern unit: mm figure 2. recommended foot print pattern external appearance in chip carrier common gnd 6 8 1 2,4 5,7,9 ant gnd 1~9 : pin no. 3 tx balanced rx (100ohm) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to ant ant to rx figure 3 - 1. electrical characteristics these data in clude loss that comes from the test board. ( approximately 0.15db) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to ant, ant to rx tx to rx isolation figure 3 - 2. electrical characteristics these data in clude loss that comes from the test board. ( approximately 0.15db) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx port figure 3 - 3. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part rx port figure 3 - 4. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part ant port figure 3 - 5. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part ant to rx (amplitude balance) ant to rx (phase balance) figure 3 - 6. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to ant (wide span) ant to rx (wide span) figure 3 - 7. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to rx (wide span) common mode isolation figure 3 - 8. electrical charact eristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part order i ng code ordering code packing reel size status d6 hh 1g960 bh9 7 - z tape & reel 3 ,000 pcs . mp d6hh1g960bh9 7 - z a tape & reel less than 3,000 pcs. mp d6hh1g960bh9 7 - u tape & reel 10 ,000 pcs . mp d6hh1g960bh9 7 - u a tape & reel less than 10 ,000 pc s . mp d6hh1g960bh9 7 - q bulk few pcs . mp * minimum order quantity ( moq ) is assigned for each inquiry , please contact to sales representatives. . *mp : mass production notice all of the contents specified herein are subject to change without notice due to technical improvements, etc. please contact t aiyo y uden co., ltd. for further details of product specifications. please conduct validation and verification of products in actual condition of mounting and operating environment before commercial s hipment of the equipment. this product is for general electronics equipment such as audio - visual equipment, household electronics, office supplies, information services and telecommunications; therefore, in case this product is used for any medical equipm ent, space equipment, nuclear equipment or disaster prevention equipment, please contact t aiyo y uden in advance. in case this product is used for general electronics equipment or circuits which require high safety and high reliability, thoroughly evaluate on safety and add a protection circuit if necessary. high frequency products fbar filter D6HH1G960BH97 features item summary w-cdma / cdma, 1008 lifecycle stage mass production standard packaging quantity (minimum) taping embossed 3000 , 10000pcs products characteristics table temperature range -20 to +85 band(3gpp) b2 band(3gpp2) bc1 use wcdma / cdma transmitting / receiving duplexer insertion loss 2.6/2.5db attenuation 56/59db rohs compliance yes halogen free yes soldering method reflow external dimensions l 2.5mm +0.1:-0.1 w 2mm +0.1:-0.1 t 0.65mm max 2015.06.03 powered by tcpdf (www.tcpdf.org) 1 / 1 spec sheet http://www.ty-top.com t h e d a t a i s r e f e r e n c e o n l y . e l e c t r i c a l c h a r a c t e r i s t i c s v a r y d e p e n d i n g o n e n v i r o n m e n t o r m e a s u r e m e n t c o n d i t i o n . t a i y o y u d e n r e s e r v e s t h e r i g h t t o m a ke c h a n g e t o t h e d a t e a t a n y t i m e w i t h o u t n o t i c e . b e f o r e m a k i n g f i n a l s e l e c t i o n , p l e a s e c h e c k p r o d u c t s p e c i f i c a t i o n . msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part table 1 - 1 . electrical specification item condition (mhz) specification unit remarks min typ max tx to ant insertion loss 1850.48~1909.52 - 2.6 3.3 db (*1 ) - - 3.0 (*2) 1850.625 ~ 1909.375 - 2.6 3. 5 - 30 ~ +85 o c (*3) ripple (any 5mhz) 1 850.48~1909.52 - - 1.5 db vswr ant 1850.48~1909.52 - 1.7 2.2 - tx - 1.8 2.2 - input power 1850.48~1909.52 29dbm, ta=+50 o c, 50kh, cw dbm absolute attenuation 10 ~ 728 30 45 - db 728 ~ 764 40 46 - db 869 ~ 894 40 48 - db 1565.42 ~ 1 573.374 43 50 - db 1573.374~1577.466 43 50 - db 1577.466~1585.42 43 50 - db 1597.5515~1605.886 43 50 - db 1605.886 ~1680 30 41 - db 1930 .48 ~ 19 89.52 43 54 - db 2110 ~ 2155 33 44 - db 2400 ~ 2500 30 35 - db 3690 ~ 3830 20 2 7 - db 5150 ~ 5350 15 19 - db 5540 ~ 5860 13 16 - db 7390 ~ 7650 10 18 - db (*1 ) specification of insertion loss ex cludes loss that comes from the test board. ( approximately 0.15db) (*2) the integrated isolation over channel band width (+/ - 1. 92mhz) (*3 ) the integrated isolation over channel band width (+/ - 0.625mhz ) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part table 1 - 2. electrical specification item condition (mhz) specification unit remarks min typ max ant to rx insertion loss 1930.48~1989.52 - 2.5 3.5 db (*1 ) ripple (any 5mhz) 1930.48~1989.52 - - 1.5 db phase balance 1930.48~1989.52 - 13 - 5 +3 +13 deg amplitude balance 1930.48~1989.52 - 1.7 - 0.6 +0.6 +1.7 db vswr ant 1930.48~1989.52 - 1.8 2.1 - rx - 1.8 2.2 - absolute attenuation 1 ~ 1850 30 38 - db 1765 ~ 1835 30 46 - db 1850 .48 ~ 19 89.52 45 55 - db 2005 ~ 2050 2 1 0 - db 2050 ~ 2075 25 43 - db 2400 ~ 2484 40 51 - db 2810 ~ 2910 25 50 - db 3755 ~ 3905 30 47 - db 5625 ~ 5815 30 42 - db tx to rx isolation (differential) 1574 ~ 1577 40 63 - db 1850.48~1909.52 52 56 - db 1932.4 ~ 1987.6 50 59 - db (*2) 1931.25~1988.75 44 59 - db - 30 ~ - 20 o c (*3) 48 - db - 20 ~ - 10 o c (*3) 50 - - db - 10 ~ +85 o c (*3) 3700 ~ 3820 30 52 - db 5550 ~ 5850 30 44 - db c ommon mode isolation 1850.48~1909.52 46 50 - db terminating impedance tx port 50 single - ended rx port 100 // none differential ant port 50 single - ended operating temperature - 20 to +85 o c device size (l typ. x w typ. x h max. ) 2.5 x 2.0 x 0.65 mm (*1 ) specification of insertion loss ex cludes loss that comes from the test board. ( approximately 0.1 5 db) (*2) the integrated isolation over channel band width (+/ - 1.92mhz) (*3 ) the integrated isolation over channel band width (+/ - 0.625mhz) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part dimensio ns < top view > < side view > < bottom view > unit: mm pin configuration pin no. pin name description 1 rx receiver pin (balanced) 2 gnd ground pin 3 tx transmitter pin 4 gnd ground pin 5 gnd ground pin 6 ant antenna pin 7 gnd ground pin 8 rx receiver pin (balanced) 9 gnd ground pin figure 1. dimensions and pin assignment <6> <2> <5> <3> <1> <2> <7> <8> <6> <3> <4> <5> <4> <1> <7> <8> max index <9> msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part evaluation circuit recommended foot print pattern unit: mm figure 2. recommended foot print pattern external appearance in chip carrier common gnd 6 8 1 2,4 5,7,9 ant gnd 1~9 : pin no. 3 tx balanced rx (100ohm) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to ant ant to rx figure 3 - 1. electrical characteristics these data in clude loss that comes from the test board. ( approximately 0.15db) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to ant, ant to rx tx to rx isolation figure 3 - 2. electrical characteristics these data in clude loss that comes from the test board. ( approximately 0.15db) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx port figure 3 - 3. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part rx port figure 3 - 4. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part ant port figure 3 - 5. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part ant to rx (amplitude balance) ant to rx (phase balance) figure 3 - 6. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to ant (wide span) ant to rx (wide span) figure 3 - 7. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to rx (wide span) common mode isolation figure 3 - 8. electrical charact eristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part order i ng code ordering code packing reel size status d6 hh 1g960 bh9 7 - z tape & reel 3 ,000 pcs . mp d6hh1g960bh9 7 - z a tape & reel less than 3,000 pcs. mp d6hh1g960bh9 7 - u tape & reel 10 ,000 pcs . mp d6hh1g960bh9 7 - u a tape & reel less than 10 ,000 pc s . mp d6hh1g960bh9 7 - q bulk few pcs . mp * minimum order quantity ( moq ) is assigned for each inquiry , please contact to sales representatives. . *mp : mass production notice all of the contents specified herein are subject to change without notice due to technical improvements, etc. please contact t aiyo y uden co., ltd. for further details of product specifications. please conduct validation and verification of products in actual condition of mounting and operating environment before commercial s hipment of the equipment. this product is for general electronics equipment such as audio - visual equipment, household electronics, office supplies, information services and telecommunications; therefore, in case this product is used for any medical equipm ent, space equipment, nuclear equipment or disaster prevention equipment, please contact t aiyo y uden in advance. in case this product is used for general electronics equipment or circuits which require high safety and high reliability, thoroughly evaluate on safety and add a protection circuit if necessary. high frequency products fbar filter D6HH1G960BH97 features item summary w-cdma / cdma, 1008 lifecycle stage mass production standard packaging quantity (minimum) taping embossed 3000 , 10000pcs products characteristics table temperature range -20 to +85 band(3gpp) b2 band(3gpp2) bc1 use wcdma / cdma transmitting / receiving duplexer insertion loss 2.6/2.5db attenuation 56/59db rohs compliance yes halogen free yes soldering method reflow external dimensions l 2.5mm +0.1:-0.1 w 2mm +0.1:-0.1 t 0.65mm max 2015.06.03 powered by tcpdf (www.tcpdf.org) 1 / 1 spec sheet http://www.ty-top.com t h e d a t a i s r e f e r e n c e o n l y . e l e c t r i c a l c h a r a c t e r i s t i c s v a r y d e p e n d i n g o n e n v i r o n m e n t o r m e a s u r e m e n t c o n d i t i o n . t a i y o y u d e n r e s e r v e s t h e r i g h t t o m a ke c h a n g e t o t h e d a t e a t a n y t i m e w i t h o u t n o t i c e . b e f o r e m a k i n g f i n a l s e l e c t i o n , p l e a s e c h e c k p r o d u c t s p e c i f i c a t i o n . msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part table 1 - 1 . electrical specification item condition (mhz) specification unit remarks min typ max tx to ant insertion loss 1850.48~1909.52 - 2.6 3.3 db (*1 ) - - 3.0 (*2) 1850.625 ~ 1909.375 - 2.6 3. 5 - 30 ~ +85 o c (*3) ripple (any 5mhz) 1 850.48~1909.52 - - 1.5 db vswr ant 1850.48~1909.52 - 1.7 2.2 - tx - 1.8 2.2 - input power 1850.48~1909.52 29dbm, ta=+50 o c, 50kh, cw dbm absolute attenuation 10 ~ 728 30 45 - db 728 ~ 764 40 46 - db 869 ~ 894 40 48 - db 1565.42 ~ 1 573.374 43 50 - db 1573.374~1577.466 43 50 - db 1577.466~1585.42 43 50 - db 1597.5515~1605.886 43 50 - db 1605.886 ~1680 30 41 - db 1930 .48 ~ 19 89.52 43 54 - db 2110 ~ 2155 33 44 - db 2400 ~ 2500 30 35 - db 3690 ~ 3830 20 2 7 - db 5150 ~ 5350 15 19 - db 5540 ~ 5860 13 16 - db 7390 ~ 7650 10 18 - db (*1 ) specification of insertion loss ex cludes loss that comes from the test board. ( approximately 0.15db) (*2) the integrated isolation over channel band width (+/ - 1. 92mhz) (*3 ) the integrated isolation over channel band width (+/ - 0.625mhz ) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part table 1 - 2. electrical specification item condition (mhz) specification unit remarks min typ max ant to rx insertion loss 1930.48~1989.52 - 2.5 3.5 db (*1 ) ripple (any 5mhz) 1930.48~1989.52 - - 1.5 db phase balance 1930.48~1989.52 - 13 - 5 +3 +13 deg amplitude balance 1930.48~1989.52 - 1.7 - 0.6 +0.6 +1.7 db vswr ant 1930.48~1989.52 - 1.8 2.1 - rx - 1.8 2.2 - absolute attenuation 1 ~ 1850 30 38 - db 1765 ~ 1835 30 46 - db 1850 .48 ~ 19 89.52 45 55 - db 2005 ~ 2050 2 1 0 - db 2050 ~ 2075 25 43 - db 2400 ~ 2484 40 51 - db 2810 ~ 2910 25 50 - db 3755 ~ 3905 30 47 - db 5625 ~ 5815 30 42 - db tx to rx isolation (differential) 1574 ~ 1577 40 63 - db 1850.48~1909.52 52 56 - db 1932.4 ~ 1987.6 50 59 - db (*2) 1931.25~1988.75 44 59 - db - 30 ~ - 20 o c (*3) 48 - db - 20 ~ - 10 o c (*3) 50 - - db - 10 ~ +85 o c (*3) 3700 ~ 3820 30 52 - db 5550 ~ 5850 30 44 - db c ommon mode isolation 1850.48~1909.52 46 50 - db terminating impedance tx port 50 single - ended rx port 100 // none differential ant port 50 single - ended operating temperature - 20 to +85 o c device size (l typ. x w typ. x h max. ) 2.5 x 2.0 x 0.65 mm (*1 ) specification of insertion loss ex cludes loss that comes from the test board. ( approximately 0.1 5 db) (*2) the integrated isolation over channel band width (+/ - 1.92mhz) (*3 ) the integrated isolation over channel band width (+/ - 0.625mhz) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part dimensio ns < top view > < side view > < bottom view > unit: mm pin configuration pin no. pin name description 1 rx receiver pin (balanced) 2 gnd ground pin 3 tx transmitter pin 4 gnd ground pin 5 gnd ground pin 6 ant antenna pin 7 gnd ground pin 8 rx receiver pin (balanced) 9 gnd ground pin figure 1. dimensions and pin assignment <6> <2> <5> <3> <1> <2> <7> <8> <6> <3> <4> <5> <4> <1> <7> <8> max index <9> msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part evaluation circuit recommended foot print pattern unit: mm figure 2. recommended foot print pattern external appearance in chip carrier common gnd 6 8 1 2,4 5,7,9 ant gnd 1~9 : pin no. 3 tx balanced rx (100ohm) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to ant ant to rx figure 3 - 1. electrical characteristics these data in clude loss that comes from the test board. ( approximately 0.15db) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to ant, ant to rx tx to rx isolation figure 3 - 2. electrical characteristics these data in clude loss that comes from the test board. ( approximately 0.15db) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx port figure 3 - 3. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part rx port figure 3 - 4. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part ant port figure 3 - 5. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part ant to rx (amplitude balance) ant to rx (phase balance) figure 3 - 6. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to ant (wide span) ant to rx (wide span) figure 3 - 7. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to rx (wide span) common mode isolation figure 3 - 8. electrical charact eristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part order i ng code ordering code packing reel size status d6 hh 1g960 bh9 7 - z tape & reel 3 ,000 pcs . mp d6hh1g960bh9 7 - z a tape & reel less than 3,000 pcs. mp d6hh1g960bh9 7 - u tape & reel 10 ,000 pcs . mp d6hh1g960bh9 7 - u a tape & reel less than 10 ,000 pc s . mp d6hh1g960bh9 7 - q bulk few pcs . mp * minimum order quantity ( moq ) is assigned for each inquiry , please contact to sales representatives. . *mp : mass production notice all of the contents specified herein are subject to change without notice due to technical improvements, etc. please contact t aiyo y uden co., ltd. for further details of product specifications. please conduct validation and verification of products in actual condition of mounting and operating environment before commercial s hipment of the equipment. this product is for general electronics equipment such as audio - visual equipment, household electronics, office supplies, information services and telecommunications; therefore, in case this product is used for any medical equipm ent, space equipment, nuclear equipment or disaster prevention equipment, please contact t aiyo y uden in advance. in case this product is used for general electronics equipment or circuits which require high safety and high reliability, thoroughly evaluate on safety and add a protection circuit if necessary. high frequency products fbar filter D6HH1G960BH97 features item summary w-cdma / cdma, 1008 lifecycle stage mass production standard packaging quantity (minimum) taping embossed 3000 , 10000pcs products characteristics table temperature range -20 to +85 band(3gpp) b2 band(3gpp2) bc1 use wcdma / cdma transmitting / receiving duplexer insertion loss 2.6/2.5db attenuation 56/59db rohs compliance yes halogen free yes soldering method reflow external dimensions l 2.5mm +0.1:-0.1 w 2mm +0.1:-0.1 t 0.65mm max 2015.06.03 powered by tcpdf (www.tcpdf.org) 1 / 1 spec sheet http://www.ty-top.com t h e d a t a i s r e f e r e n c e o n l y . e l e c t r i c a l c h a r a c t e r i s t i c s v a r y d e p e n d i n g o n e n v i r o n m e n t o r m e a s u r e m e n t c o n d i t i o n . t a i y o y u d e n r e s e r v e s t h e r i g h t t o m a ke c h a n g e t o t h e d a t e a t a n y t i m e w i t h o u t n o t i c e . b e f o r e m a k i n g f i n a l s e l e c t i o n , p l e a s e c h e c k p r o d u c t s p e c i f i c a t i o n . msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part table 1 - 1 . electrical specification item condition (mhz) specification unit remarks min typ max tx to ant insertion loss 1850.48~1909.52 - 2.6 3.3 db (*1 ) - - 3.0 (*2) 1850.625 ~ 1909.375 - 2.6 3. 5 - 30 ~ +85 o c (*3) ripple (any 5mhz) 1 850.48~1909.52 - - 1.5 db vswr ant 1850.48~1909.52 - 1.7 2.2 - tx - 1.8 2.2 - input power 1850.48~1909.52 29dbm, ta=+50 o c, 50kh, cw dbm absolute attenuation 10 ~ 728 30 45 - db 728 ~ 764 40 46 - db 869 ~ 894 40 48 - db 1565.42 ~ 1 573.374 43 50 - db 1573.374~1577.466 43 50 - db 1577.466~1585.42 43 50 - db 1597.5515~1605.886 43 50 - db 1605.886 ~1680 30 41 - db 1930 .48 ~ 19 89.52 43 54 - db 2110 ~ 2155 33 44 - db 2400 ~ 2500 30 35 - db 3690 ~ 3830 20 2 7 - db 5150 ~ 5350 15 19 - db 5540 ~ 5860 13 16 - db 7390 ~ 7650 10 18 - db (*1 ) specification of insertion loss ex cludes loss that comes from the test board. ( approximately 0.15db) (*2) the integrated isolation over channel band width (+/ - 1. 92mhz) (*3 ) the integrated isolation over channel band width (+/ - 0.625mhz ) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part table 1 - 2. electrical specification item condition (mhz) specification unit remarks min typ max ant to rx insertion loss 1930.48~1989.52 - 2.5 3.5 db (*1 ) ripple (any 5mhz) 1930.48~1989.52 - - 1.5 db phase balance 1930.48~1989.52 - 13 - 5 +3 +13 deg amplitude balance 1930.48~1989.52 - 1.7 - 0.6 +0.6 +1.7 db vswr ant 1930.48~1989.52 - 1.8 2.1 - rx - 1.8 2.2 - absolute attenuation 1 ~ 1850 30 38 - db 1765 ~ 1835 30 46 - db 1850 .48 ~ 19 89.52 45 55 - db 2005 ~ 2050 2 1 0 - db 2050 ~ 2075 25 43 - db 2400 ~ 2484 40 51 - db 2810 ~ 2910 25 50 - db 3755 ~ 3905 30 47 - db 5625 ~ 5815 30 42 - db tx to rx isolation (differential) 1574 ~ 1577 40 63 - db 1850.48~1909.52 52 56 - db 1932.4 ~ 1987.6 50 59 - db (*2) 1931.25~1988.75 44 59 - db - 30 ~ - 20 o c (*3) 48 - db - 20 ~ - 10 o c (*3) 50 - - db - 10 ~ +85 o c (*3) 3700 ~ 3820 30 52 - db 5550 ~ 5850 30 44 - db c ommon mode isolation 1850.48~1909.52 46 50 - db terminating impedance tx port 50 single - ended rx port 100 // none differential ant port 50 single - ended operating temperature - 20 to +85 o c device size (l typ. x w typ. x h max. ) 2.5 x 2.0 x 0.65 mm (*1 ) specification of insertion loss ex cludes loss that comes from the test board. ( approximately 0.1 5 db) (*2) the integrated isolation over channel band width (+/ - 1.92mhz) (*3 ) the integrated isolation over channel band width (+/ - 0.625mhz) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part dimensio ns < top view > < side view > < bottom view > unit: mm pin configuration pin no. pin name description 1 rx receiver pin (balanced) 2 gnd ground pin 3 tx transmitter pin 4 gnd ground pin 5 gnd ground pin 6 ant antenna pin 7 gnd ground pin 8 rx receiver pin (balanced) 9 gnd ground pin figure 1. dimensions and pin assignment <6> <2> <5> <3> <1> <2> <7> <8> <6> <3> <4> <5> <4> <1> <7> <8> max index <9> msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part evaluation circuit recommended foot print pattern unit: mm figure 2. recommended foot print pattern external appearance in chip carrier common gnd 6 8 1 2,4 5,7,9 ant gnd 1~9 : pin no. 3 tx balanced rx (100ohm) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to ant ant to rx figure 3 - 1. electrical characteristics these data in clude loss that comes from the test board. ( approximately 0.15db) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to ant, ant to rx tx to rx isolation figure 3 - 2. electrical characteristics these data in clude loss that comes from the test board. ( approximately 0.15db) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx port figure 3 - 3. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part rx port figure 3 - 4. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part ant port figure 3 - 5. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part ant to rx (amplitude balance) ant to rx (phase balance) figure 3 - 6. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to ant (wide span) ant to rx (wide span) figure 3 - 7. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to rx (wide span) common mode isolation figure 3 - 8. electrical charact eristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part order i ng code ordering code packing reel size status d6 hh 1g960 bh9 7 - z tape & reel 3 ,000 pcs . mp d6hh1g960bh9 7 - z a tape & reel less than 3,000 pcs. mp d6hh1g960bh9 7 - u tape & reel 10 ,000 pcs . mp d6hh1g960bh9 7 - u a tape & reel less than 10 ,000 pc s . mp d6hh1g960bh9 7 - q bulk few pcs . mp * minimum order quantity ( moq ) is assigned for each inquiry , please contact to sales representatives. . *mp : mass production notice all of the contents specified herein are subject to change without notice due to technical improvements, etc. please contact t aiyo y uden co., ltd. for further details of product specifications. please conduct validation and verification of products in actual condition of mounting and operating environment before commercial s hipment of the equipment. this product is for general electronics equipment such as audio - visual equipment, household electronics, office supplies, information services and telecommunications; therefore, in case this product is used for any medical equipm ent, space equipment, nuclear equipment or disaster prevention equipment, please contact t aiyo y uden in advance. in case this product is used for general electronics equipment or circuits which require high safety and high reliability, thoroughly evaluate on safety and add a protection circuit if necessary. high frequency products fbar filter D6HH1G960BH97 features item summary w-cdma / cdma, 1008 lifecycle stage mass production standard packaging quantity (minimum) taping embossed 3000 , 10000pcs products characteristics table temperature range -20 to +85 band(3gpp) b2 band(3gpp2) bc1 use wcdma / cdma transmitting / receiving duplexer insertion loss 2.6/2.5db attenuation 56/59db rohs compliance yes halogen free yes soldering method reflow external dimensions l 2.5mm +0.1:-0.1 w 2mm +0.1:-0.1 t 0.65mm max 2015.06.03 powered by tcpdf (www.tcpdf.org) 1 / 1 spec sheet http://www.ty-top.com t h e d a t a i s r e f e r e n c e o n l y . e l e c t r i c a l c h a r a c t e r i s t i c s v a r y d e p e n d i n g o n e n v i r o n m e n t o r m e a s u r e m e n t c o n d i t i o n . t a i y o y u d e n r e s e r v e s t h e r i g h t t o m a ke c h a n g e t o t h e d a t e a t a n y t i m e w i t h o u t n o t i c e . b e f o r e m a k i n g f i n a l s e l e c t i o n , p l e a s e c h e c k p r o d u c t s p e c i f i c a t i o n . msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part table 1 - 1 . electrical specification item condition (mhz) specification unit remarks min typ max tx to ant insertion loss 1850.48~1909.52 - 2.6 3.3 db (*1 ) - - 3.0 (*2) 1850.625 ~ 1909.375 - 2.6 3. 5 - 30 ~ +85 o c (*3) ripple (any 5mhz) 1 850.48~1909.52 - - 1.5 db vswr ant 1850.48~1909.52 - 1.7 2.2 - tx - 1.8 2.2 - input power 1850.48~1909.52 29dbm, ta=+50 o c, 50kh, cw dbm absolute attenuation 10 ~ 728 30 45 - db 728 ~ 764 40 46 - db 869 ~ 894 40 48 - db 1565.42 ~ 1 573.374 43 50 - db 1573.374~1577.466 43 50 - db 1577.466~1585.42 43 50 - db 1597.5515~1605.886 43 50 - db 1605.886 ~1680 30 41 - db 1930 .48 ~ 19 89.52 43 54 - db 2110 ~ 2155 33 44 - db 2400 ~ 2500 30 35 - db 3690 ~ 3830 20 2 7 - db 5150 ~ 5350 15 19 - db 5540 ~ 5860 13 16 - db 7390 ~ 7650 10 18 - db (*1 ) specification of insertion loss ex cludes loss that comes from the test board. ( approximately 0.15db) (*2) the integrated isolation over channel band width (+/ - 1. 92mhz) (*3 ) the integrated isolation over channel band width (+/ - 0.625mhz ) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part table 1 - 2. electrical specification item condition (mhz) specification unit remarks min typ max ant to rx insertion loss 1930.48~1989.52 - 2.5 3.5 db (*1 ) ripple (any 5mhz) 1930.48~1989.52 - - 1.5 db phase balance 1930.48~1989.52 - 13 - 5 +3 +13 deg amplitude balance 1930.48~1989.52 - 1.7 - 0.6 +0.6 +1.7 db vswr ant 1930.48~1989.52 - 1.8 2.1 - rx - 1.8 2.2 - absolute attenuation 1 ~ 1850 30 38 - db 1765 ~ 1835 30 46 - db 1850 .48 ~ 19 89.52 45 55 - db 2005 ~ 2050 2 1 0 - db 2050 ~ 2075 25 43 - db 2400 ~ 2484 40 51 - db 2810 ~ 2910 25 50 - db 3755 ~ 3905 30 47 - db 5625 ~ 5815 30 42 - db tx to rx isolation (differential) 1574 ~ 1577 40 63 - db 1850.48~1909.52 52 56 - db 1932.4 ~ 1987.6 50 59 - db (*2) 1931.25~1988.75 44 59 - db - 30 ~ - 20 o c (*3) 48 - db - 20 ~ - 10 o c (*3) 50 - - db - 10 ~ +85 o c (*3) 3700 ~ 3820 30 52 - db 5550 ~ 5850 30 44 - db c ommon mode isolation 1850.48~1909.52 46 50 - db terminating impedance tx port 50 single - ended rx port 100 // none differential ant port 50 single - ended operating temperature - 20 to +85 o c device size (l typ. x w typ. x h max. ) 2.5 x 2.0 x 0.65 mm (*1 ) specification of insertion loss ex cludes loss that comes from the test board. ( approximately 0.1 5 db) (*2) the integrated isolation over channel band width (+/ - 1.92mhz) (*3 ) the integrated isolation over channel band width (+/ - 0.625mhz) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part dimensio ns < top view > < side view > < bottom view > unit: mm pin configuration pin no. pin name description 1 rx receiver pin (balanced) 2 gnd ground pin 3 tx transmitter pin 4 gnd ground pin 5 gnd ground pin 6 ant antenna pin 7 gnd ground pin 8 rx receiver pin (balanced) 9 gnd ground pin figure 1. dimensions and pin assignment <6> <2> <5> <3> <1> <2> <7> <8> <6> <3> <4> <5> <4> <1> <7> <8> max index <9> msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part evaluation circuit recommended foot print pattern unit: mm figure 2. recommended foot print pattern external appearance in chip carrier common gnd 6 8 1 2,4 5,7,9 ant gnd 1~9 : pin no. 3 tx balanced rx (100ohm) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to ant ant to rx figure 3 - 1. electrical characteristics these data in clude loss that comes from the test board. ( approximately 0.15db) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to ant, ant to rx tx to rx isolation figure 3 - 2. electrical characteristics these data in clude loss that comes from the test board. ( approximately 0.15db) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx port figure 3 - 3. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part rx port figure 3 - 4. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part ant port figure 3 - 5. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part ant to rx (amplitude balance) ant to rx (phase balance) figure 3 - 6. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to ant (wide span) ant to rx (wide span) figure 3 - 7. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to rx (wide span) common mode isolation figure 3 - 8. electrical charact eristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part order i ng code ordering code packing reel size status d6 hh 1g960 bh9 7 - z tape & reel 3 ,000 pcs . mp d6hh1g960bh9 7 - z a tape & reel less than 3,000 pcs. mp d6hh1g960bh9 7 - u tape & reel 10 ,000 pcs . mp d6hh1g960bh9 7 - u a tape & reel less than 10 ,000 pc s . mp d6hh1g960bh9 7 - q bulk few pcs . mp * minimum order quantity ( moq ) is assigned for each inquiry , please contact to sales representatives. . *mp : mass production notice all of the contents specified herein are subject to change without notice due to technical improvements, etc. please contact t aiyo y uden co., ltd. for further details of product specifications. please conduct validation and verification of products in actual condition of mounting and operating environment before commercial s hipment of the equipment. this product is for general electronics equipment such as audio - visual equipment, household electronics, office supplies, information services and telecommunications; therefore, in case this product is used for any medical equipm ent, space equipment, nuclear equipment or disaster prevention equipment, please contact t aiyo y uden in advance. in case this product is used for general electronics equipment or circuits which require high safety and high reliability, thoroughly evaluate on safety and add a protection circuit if necessary. high frequency products fbar filter D6HH1G960BH97 features item summary w-cdma / cdma, 1008 lifecycle stage mass production standard packaging quantity (minimum) taping embossed 3000 , 10000pcs products characteristics table temperature range -20 to +85 band(3gpp) b2 band(3gpp2) bc1 use wcdma / cdma transmitting / receiving duplexer insertion loss 2.6/2.5db attenuation 56/59db rohs compliance yes halogen free yes soldering method reflow external dimensions l 2.5mm +0.1:-0.1 w 2mm +0.1:-0.1 t 0.65mm max 2015.06.03 powered by tcpdf (www.tcpdf.org) 1 / 1 spec sheet http://www.ty-top.com t h e d a t a i s r e f e r e n c e o n l y . e l e c t r i c a l c h a r a c t e r i s t i c s v a r y d e p e n d i n g o n e n v i r o n m e n t o r m e a s u r e m e n t c o n d i t i o n . t a i y o y u d e n r e s e r v e s t h e r i g h t t o m a ke c h a n g e t o t h e d a t e a t a n y t i m e w i t h o u t n o t i c e . b e f o r e m a k i n g f i n a l s e l e c t i o n , p l e a s e c h e c k p r o d u c t s p e c i f i c a t i o n . msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part table 1 - 1 . electrical specification item condition (mhz) specification unit remarks min typ max tx to ant insertion loss 1850.48~1909.52 - 2.6 3.3 db (*1 ) - - 3.0 (*2) 1850.625 ~ 1909.375 - 2.6 3. 5 - 30 ~ +85 o c (*3) ripple (any 5mhz) 1 850.48~1909.52 - - 1.5 db vswr ant 1850.48~1909.52 - 1.7 2.2 - tx - 1.8 2.2 - input power 1850.48~1909.52 29dbm, ta=+50 o c, 50kh, cw dbm absolute attenuation 10 ~ 728 30 45 - db 728 ~ 764 40 46 - db 869 ~ 894 40 48 - db 1565.42 ~ 1 573.374 43 50 - db 1573.374~1577.466 43 50 - db 1577.466~1585.42 43 50 - db 1597.5515~1605.886 43 50 - db 1605.886 ~1680 30 41 - db 1930 .48 ~ 19 89.52 43 54 - db 2110 ~ 2155 33 44 - db 2400 ~ 2500 30 35 - db 3690 ~ 3830 20 2 7 - db 5150 ~ 5350 15 19 - db 5540 ~ 5860 13 16 - db 7390 ~ 7650 10 18 - db (*1 ) specification of insertion loss ex cludes loss that comes from the test board. ( approximately 0.15db) (*2) the integrated isolation over channel band width (+/ - 1. 92mhz) (*3 ) the integrated isolation over channel band width (+/ - 0.625mhz ) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part table 1 - 2. electrical specification item condition (mhz) specification unit remarks min typ max ant to rx insertion loss 1930.48~1989.52 - 2.5 3.5 db (*1 ) ripple (any 5mhz) 1930.48~1989.52 - - 1.5 db phase balance 1930.48~1989.52 - 13 - 5 +3 +13 deg amplitude balance 1930.48~1989.52 - 1.7 - 0.6 +0.6 +1.7 db vswr ant 1930.48~1989.52 - 1.8 2.1 - rx - 1.8 2.2 - absolute attenuation 1 ~ 1850 30 38 - db 1765 ~ 1835 30 46 - db 1850 .48 ~ 19 89.52 45 55 - db 2005 ~ 2050 2 1 0 - db 2050 ~ 2075 25 43 - db 2400 ~ 2484 40 51 - db 2810 ~ 2910 25 50 - db 3755 ~ 3905 30 47 - db 5625 ~ 5815 30 42 - db tx to rx isolation (differential) 1574 ~ 1577 40 63 - db 1850.48~1909.52 52 56 - db 1932.4 ~ 1987.6 50 59 - db (*2) 1931.25~1988.75 44 59 - db - 30 ~ - 20 o c (*3) 48 - db - 20 ~ - 10 o c (*3) 50 - - db - 10 ~ +85 o c (*3) 3700 ~ 3820 30 52 - db 5550 ~ 5850 30 44 - db c ommon mode isolation 1850.48~1909.52 46 50 - db terminating impedance tx port 50 single - ended rx port 100 // none differential ant port 50 single - ended operating temperature - 20 to +85 o c device size (l typ. x w typ. x h max. ) 2.5 x 2.0 x 0.65 mm (*1 ) specification of insertion loss ex cludes loss that comes from the test board. ( approximately 0.1 5 db) (*2) the integrated isolation over channel band width (+/ - 1.92mhz) (*3 ) the integrated isolation over channel band width (+/ - 0.625mhz) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part dimensio ns < top view > < side view > < bottom view > unit: mm pin configuration pin no. pin name description 1 rx receiver pin (balanced) 2 gnd ground pin 3 tx transmitter pin 4 gnd ground pin 5 gnd ground pin 6 ant antenna pin 7 gnd ground pin 8 rx receiver pin (balanced) 9 gnd ground pin figure 1. dimensions and pin assignment <6> <2> <5> <3> <1> <2> <7> <8> <6> <3> <4> <5> <4> <1> <7> <8> max index <9> msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part evaluation circuit recommended foot print pattern unit: mm figure 2. recommended foot print pattern external appearance in chip carrier common gnd 6 8 1 2,4 5,7,9 ant gnd 1~9 : pin no. 3 tx balanced rx (100ohm) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to ant ant to rx figure 3 - 1. electrical characteristics these data in clude loss that comes from the test board. ( approximately 0.15db) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to ant, ant to rx tx to rx isolation figure 3 - 2. electrical characteristics these data in clude loss that comes from the test board. ( approximately 0.15db) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx port figure 3 - 3. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part rx port figure 3 - 4. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part ant port figure 3 - 5. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part ant to rx (amplitude balance) ant to rx (phase balance) figure 3 - 6. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to ant (wide span) ant to rx (wide span) figure 3 - 7. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to rx (wide span) common mode isolation figure 3 - 8. electrical charact eristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part order i ng code ordering code packing reel size status d6 hh 1g960 bh9 7 - z tape & reel 3 ,000 pcs . mp d6hh1g960bh9 7 - z a tape & reel less than 3,000 pcs. mp d6hh1g960bh9 7 - u tape & reel 10 ,000 pcs . mp d6hh1g960bh9 7 - u a tape & reel less than 10 ,000 pc s . mp d6hh1g960bh9 7 - q bulk few pcs . mp * minimum order quantity ( moq ) is assigned for each inquiry , please contact to sales representatives. . *mp : mass production notice all of the contents specified herein are subject to change without notice due to technical improvements, etc. please contact t aiyo y uden co., ltd. for further details of product specifications. please conduct validation and verification of products in actual condition of mounting and operating environment before commercial s hipment of the equipment. this product is for general electronics equipment such as audio - visual equipment, household electronics, office supplies, information services and telecommunications; therefore, in case this product is used for any medical equipm ent, space equipment, nuclear equipment or disaster prevention equipment, please contact t aiyo y uden in advance. in case this product is used for general electronics equipment or circuits which require high safety and high reliability, thoroughly evaluate on safety and add a protection circuit if necessary. high frequency products fbar filter D6HH1G960BH97 features item summary w-cdma / cdma, 1008 lifecycle stage mass production standard packaging quantity (minimum) taping embossed 3000 , 10000pcs products characteristics table temperature range -20 to +85 band(3gpp) b2 band(3gpp2) bc1 use wcdma / cdma transmitting / receiving duplexer insertion loss 2.6/2.5db attenuation 56/59db rohs compliance yes halogen free yes soldering method reflow external dimensions l 2.5mm +0.1:-0.1 w 2mm +0.1:-0.1 t 0.65mm max 2015.06.03 powered by tcpdf (www.tcpdf.org) 1 / 1 spec sheet http://www.ty-top.com t h e d a t a i s r e f e r e n c e o n l y . e l e c t r i c a l c h a r a c t e r i s t i c s v a r y d e p e n d i n g o n e n v i r o n m e n t o r m e a s u r e m e n t c o n d i t i o n . t a i y o y u d e n r e s e r v e s t h e r i g h t t o m a ke c h a n g e t o t h e d a t e a t a n y t i m e w i t h o u t n o t i c e . b e f o r e m a k i n g f i n a l s e l e c t i o n , p l e a s e c h e c k p r o d u c t s p e c i f i c a t i o n . msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part table 1 - 1 . electrical specification item condition (mhz) specification unit remarks min typ max tx to ant insertion loss 1850.48~1909.52 - 2.6 3.3 db (*1 ) - - 3.0 (*2) 1850.625 ~ 1909.375 - 2.6 3. 5 - 30 ~ +85 o c (*3) ripple (any 5mhz) 1 850.48~1909.52 - - 1.5 db vswr ant 1850.48~1909.52 - 1.7 2.2 - tx - 1.8 2.2 - input power 1850.48~1909.52 29dbm, ta=+50 o c, 50kh, cw dbm absolute attenuation 10 ~ 728 30 45 - db 728 ~ 764 40 46 - db 869 ~ 894 40 48 - db 1565.42 ~ 1 573.374 43 50 - db 1573.374~1577.466 43 50 - db 1577.466~1585.42 43 50 - db 1597.5515~1605.886 43 50 - db 1605.886 ~1680 30 41 - db 1930 .48 ~ 19 89.52 43 54 - db 2110 ~ 2155 33 44 - db 2400 ~ 2500 30 35 - db 3690 ~ 3830 20 2 7 - db 5150 ~ 5350 15 19 - db 5540 ~ 5860 13 16 - db 7390 ~ 7650 10 18 - db (*1 ) specification of insertion loss ex cludes loss that comes from the test board. ( approximately 0.15db) (*2) the integrated isolation over channel band width (+/ - 1. 92mhz) (*3 ) the integrated isolation over channel band width (+/ - 0.625mhz ) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part table 1 - 2. electrical specification item condition (mhz) specification unit remarks min typ max ant to rx insertion loss 1930.48~1989.52 - 2.5 3.5 db (*1 ) ripple (any 5mhz) 1930.48~1989.52 - - 1.5 db phase balance 1930.48~1989.52 - 13 - 5 +3 +13 deg amplitude balance 1930.48~1989.52 - 1.7 - 0.6 +0.6 +1.7 db vswr ant 1930.48~1989.52 - 1.8 2.1 - rx - 1.8 2.2 - absolute attenuation 1 ~ 1850 30 38 - db 1765 ~ 1835 30 46 - db 1850 .48 ~ 19 89.52 45 55 - db 2005 ~ 2050 2 1 0 - db 2050 ~ 2075 25 43 - db 2400 ~ 2484 40 51 - db 2810 ~ 2910 25 50 - db 3755 ~ 3905 30 47 - db 5625 ~ 5815 30 42 - db tx to rx isolation (differential) 1574 ~ 1577 40 63 - db 1850.48~1909.52 52 56 - db 1932.4 ~ 1987.6 50 59 - db (*2) 1931.25~1988.75 44 59 - db - 30 ~ - 20 o c (*3) 48 - db - 20 ~ - 10 o c (*3) 50 - - db - 10 ~ +85 o c (*3) 3700 ~ 3820 30 52 - db 5550 ~ 5850 30 44 - db c ommon mode isolation 1850.48~1909.52 46 50 - db terminating impedance tx port 50 single - ended rx port 100 // none differential ant port 50 single - ended operating temperature - 20 to +85 o c device size (l typ. x w typ. x h max. ) 2.5 x 2.0 x 0.65 mm (*1 ) specification of insertion loss ex cludes loss that comes from the test board. ( approximately 0.1 5 db) (*2) the integrated isolation over channel band width (+/ - 1.92mhz) (*3 ) the integrated isolation over channel band width (+/ - 0.625mhz) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part dimensio ns < top view > < side view > < bottom view > unit: mm pin configuration pin no. pin name description 1 rx receiver pin (balanced) 2 gnd ground pin 3 tx transmitter pin 4 gnd ground pin 5 gnd ground pin 6 ant antenna pin 7 gnd ground pin 8 rx receiver pin (balanced) 9 gnd ground pin figure 1. dimensions and pin assignment <6> <2> <5> <3> <1> <2> <7> <8> <6> <3> <4> <5> <4> <1> <7> <8> max index <9> msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part evaluation circuit recommended foot print pattern unit: mm figure 2. recommended foot print pattern external appearance in chip carrier common gnd 6 8 1 2,4 5,7,9 ant gnd 1~9 : pin no. 3 tx balanced rx (100ohm) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to ant ant to rx figure 3 - 1. electrical characteristics these data in clude loss that comes from the test board. ( approximately 0.15db) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to ant, ant to rx tx to rx isolation figure 3 - 2. electrical characteristics these data in clude loss that comes from the test board. ( approximately 0.15db) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx port figure 3 - 3. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part rx port figure 3 - 4. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part ant port figure 3 - 5. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part ant to rx (amplitude balance) ant to rx (phase balance) figure 3 - 6. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to ant (wide span) ant to rx (wide span) figure 3 - 7. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to rx (wide span) common mode isolation figure 3 - 8. electrical charact eristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part order i ng code ordering code packing reel size status d6 hh 1g960 bh9 7 - z tape & reel 3 ,000 pcs . mp d6hh1g960bh9 7 - z a tape & reel less than 3,000 pcs. mp d6hh1g960bh9 7 - u tape & reel 10 ,000 pcs . mp d6hh1g960bh9 7 - u a tape & reel less than 10 ,000 pc s . mp d6hh1g960bh9 7 - q bulk few pcs . mp * minimum order quantity ( moq ) is assigned for each inquiry , please contact to sales representatives. . *mp : mass production notice all of the contents specified herein are subject to change without notice due to technical improvements, etc. please contact t aiyo y uden co., ltd. for further details of product specifications. please conduct validation and verification of products in actual condition of mounting and operating environment before commercial s hipment of the equipment. this product is for general electronics equipment such as audio - visual equipment, household electronics, office supplies, information services and telecommunications; therefore, in case this product is used for any medical equipm ent, space equipment, nuclear equipment or disaster prevention equipment, please contact t aiyo y uden in advance. in case this product is used for general electronics equipment or circuits which require high safety and high reliability, thoroughly evaluate on safety and add a protection circuit if necessary. high frequency products fbar filter D6HH1G960BH97 features item summary w-cdma / cdma, 1008 lifecycle stage mass production standard packaging quantity (minimum) taping embossed 3000 , 10000pcs products characteristics table temperature range -20 to +85 band(3gpp) b2 band(3gpp2) bc1 use wcdma / cdma transmitting / receiving duplexer insertion loss 2.6/2.5db attenuation 56/59db rohs compliance yes halogen free yes soldering method reflow external dimensions l 2.5mm +0.1:-0.1 w 2mm +0.1:-0.1 t 0.65mm max 2015.06.03 powered by tcpdf (www.tcpdf.org) 1 / 1 spec sheet http://www.ty-top.com t h e d a t a i s r e f e r e n c e o n l y . e l e c t r i c a l c h a r a c t e r i s t i c s v a r y d e p e n d i n g o n e n v i r o n m e n t o r m e a s u r e m e n t c o n d i t i o n . t a i y o y u d e n r e s e r v e s t h e r i g h t t o m a ke c h a n g e t o t h e d a t e a t a n y t i m e w i t h o u t n o t i c e . b e f o r e m a k i n g f i n a l s e l e c t i o n , p l e a s e c h e c k p r o d u c t s p e c i f i c a t i o n . msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part table 1 - 1 . electrical specification item condition (mhz) specification unit remarks min typ max tx to ant insertion loss 1850.48~1909.52 - 2.6 3.3 db (*1 ) - - 3.0 (*2) 1850.625 ~ 1909.375 - 2.6 3. 5 - 30 ~ +85 o c (*3) ripple (any 5mhz) 1 850.48~1909.52 - - 1.5 db vswr ant 1850.48~1909.52 - 1.7 2.2 - tx - 1.8 2.2 - input power 1850.48~1909.52 29dbm, ta=+50 o c, 50kh, cw dbm absolute attenuation 10 ~ 728 30 45 - db 728 ~ 764 40 46 - db 869 ~ 894 40 48 - db 1565.42 ~ 1 573.374 43 50 - db 1573.374~1577.466 43 50 - db 1577.466~1585.42 43 50 - db 1597.5515~1605.886 43 50 - db 1605.886 ~1680 30 41 - db 1930 .48 ~ 19 89.52 43 54 - db 2110 ~ 2155 33 44 - db 2400 ~ 2500 30 35 - db 3690 ~ 3830 20 2 7 - db 5150 ~ 5350 15 19 - db 5540 ~ 5860 13 16 - db 7390 ~ 7650 10 18 - db (*1 ) specification of insertion loss ex cludes loss that comes from the test board. ( approximately 0.15db) (*2) the integrated isolation over channel band width (+/ - 1. 92mhz) (*3 ) the integrated isolation over channel band width (+/ - 0.625mhz ) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part table 1 - 2. electrical specification item condition (mhz) specification unit remarks min typ max ant to rx insertion loss 1930.48~1989.52 - 2.5 3.5 db (*1 ) ripple (any 5mhz) 1930.48~1989.52 - - 1.5 db phase balance 1930.48~1989.52 - 13 - 5 +3 +13 deg amplitude balance 1930.48~1989.52 - 1.7 - 0.6 +0.6 +1.7 db vswr ant 1930.48~1989.52 - 1.8 2.1 - rx - 1.8 2.2 - absolute attenuation 1 ~ 1850 30 38 - db 1765 ~ 1835 30 46 - db 1850 .48 ~ 19 89.52 45 55 - db 2005 ~ 2050 2 1 0 - db 2050 ~ 2075 25 43 - db 2400 ~ 2484 40 51 - db 2810 ~ 2910 25 50 - db 3755 ~ 3905 30 47 - db 5625 ~ 5815 30 42 - db tx to rx isolation (differential) 1574 ~ 1577 40 63 - db 1850.48~1909.52 52 56 - db 1932.4 ~ 1987.6 50 59 - db (*2) 1931.25~1988.75 44 59 - db - 30 ~ - 20 o c (*3) 48 - db - 20 ~ - 10 o c (*3) 50 - - db - 10 ~ +85 o c (*3) 3700 ~ 3820 30 52 - db 5550 ~ 5850 30 44 - db c ommon mode isolation 1850.48~1909.52 46 50 - db terminating impedance tx port 50 single - ended rx port 100 // none differential ant port 50 single - ended operating temperature - 20 to +85 o c device size (l typ. x w typ. x h max. ) 2.5 x 2.0 x 0.65 mm (*1 ) specification of insertion loss ex cludes loss that comes from the test board. ( approximately 0.1 5 db) (*2) the integrated isolation over channel band width (+/ - 1.92mhz) (*3 ) the integrated isolation over channel band width (+/ - 0.625mhz) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part dimensio ns < top view > < side view > < bottom view > unit: mm pin configuration pin no. pin name description 1 rx receiver pin (balanced) 2 gnd ground pin 3 tx transmitter pin 4 gnd ground pin 5 gnd ground pin 6 ant antenna pin 7 gnd ground pin 8 rx receiver pin (balanced) 9 gnd ground pin figure 1. dimensions and pin assignment <6> <2> <5> <3> <1> <2> <7> <8> <6> <3> <4> <5> <4> <1> <7> <8> max index <9> msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part evaluation circuit recommended foot print pattern unit: mm figure 2. recommended foot print pattern external appearance in chip carrier common gnd 6 8 1 2,4 5,7,9 ant gnd 1~9 : pin no. 3 tx balanced rx (100ohm) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to ant ant to rx figure 3 - 1. electrical characteristics these data in clude loss that comes from the test board. ( approximately 0.15db) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to ant, ant to rx tx to rx isolation figure 3 - 2. electrical characteristics these data in clude loss that comes from the test board. ( approximately 0.15db) msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx port figure 3 - 3. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part rx port figure 3 - 4. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part ant port figure 3 - 5. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part ant to rx (amplitude balance) ant to rx (phase balance) figure 3 - 6. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to ant (wide span) ant to rx (wide span) figure 3 - 7. electrical characteristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part tx to rx (wide span) common mode isolation figure 3 - 8. electrical charact eristics msl1 customer name standard system w - cdma band ii / cdma2000 bc 1 duplexer date apr 2 , 201 2 part number d6hh1g960bh9 7 version 2 .0 fe final pb - free p b * pb free part order i ng code ordering code packing reel size status d6 hh 1g960 bh9 7 - z tape & reel 3 ,000 pcs . mp d6hh1g960bh9 7 - z a tape & reel less than 3,000 pcs. mp d6hh1g960bh9 7 - u tape & reel 10 ,000 pcs . mp d6hh1g960bh9 7 - u a tape & reel less than 10 ,000 pc s . mp d6hh1g960bh9 7 - q bulk few pcs . mp * minimum order quantity ( moq ) is assigned for each inquiry , please contact to sales representatives. . *mp : mass production notice all of the contents specified herein are subject to change without notice due to technical improvements, etc. please contact t aiyo y uden co., ltd. for further details of product specifications. please conduct validation and verification of products in actual condition of mounting and operating environment before commercial s hipment of the equipment. this product is for general electronics equipment such as audio - visual equipment, household electronics, office supplies, information services and telecommunications; therefore, in case this product is used for any medical equipm ent, space equipment, nuclear equipment or disaster prevention equipment, please contact t aiyo y uden in advance. in case this product is used for general electronics equipment or circuits which require high safety and high reliability, thoroughly evaluate on safety and add a protection circuit if necessary. |
Price & Availability of D6HH1G960BH97 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |